INSTALLATION INSTRUCTIONS
RHD6_EB & RHD8_EB
QUARTZ RESTRIKE (QR) & DCB
Housing with Quartz Restrike Option - (Factory Wired):
Install the housing per the installation instructions provided with the housing.
Open Reflectors:
1. After the housing is installed, extend the QR/DCB conduit assembly down through the housing aperture as shown.
2.
Place the end of the cast socketholder through the 7/8" diameter hole in the side of the reflector
. Secure it in position by pushing
the retaining clip onto the dentents on the end of the socketholder from the inside of the reflector. (See illustration on other side.)
3. Place the reflector in the housing aperture. Make sure the two mounting screws extend through the keyholes in the top of the
reflector.
Tighten the screws to draw the trim ring up flush against the ceiling.
4. Install correct double contact bayonet base quartz lamp per table on other side.
B
allast
QR/DCB
Conduit Assembly
I
MPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
a
nd instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
a
nd proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
d
uring servicing or relamping, turn off power at fuse or circuit breaker.
A
ll servicing or relamping must be performed by
q
ualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
P
roduct must be mounted in locations and at heights and in a manner consistent with its intended use, and in
c
ompliance with the National Electrical Code and local codes.
T
he use of accessory equipment not recommended by
t
he manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
p
roduct in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
t
he like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
Reflector
DCB or 120V QR Shown
277V QR version will include a Step-Down
T