Prescolite BX4-12 User Manual

Browse online or download User Manual for Lighting Prescolite BX4-12. Prescolite BX4-12 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Instruction
Sheet
Part No...........................................
With representatives offices in principal cities throughout North America.
Copyright , revision, All Rights Reserved - Printed in U.S.A.
701 Millennium Blvd., Greenville, SC 29607
www.prescolite.com
Prescolite Toll Free Technical Support
1.888.PRS.4TEC
Hours: 8am - 5pm ET
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install i
n areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker.
All servicing or relamping must be performed by
qualified service personnel. Product must be grounde
d to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory e
quipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains
, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
93010070
Sheet 1 of 2
2012 09/25/12
BX4-12
WARNING: When using special control devices with this fixture, follow instructions carefully to ensure N.E.C.
compliance. For more help, contact a qualified electrical contractor.
WARNING: This product contains chemicals
known to the State of California to cause cancer, birth defects
and/or other reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise
touching this product.
CAUTION: RISK OF FIRE: Recessed portions of recessed housi
ng, other than at points of support, shall be
spaced at least ½ inch from combustible material. Thermal insulation shall not be installed within 3 inches of
recessed housing or junction box, and shall not be installed above fixture as to entrap heat and pr
event the
free circulation of air.
CAUTION: To complete the installation, choose only UL listed Prescolite trims from the label inside the
housing. The use of any trim not listed in this fixture is a violation of N.E.C. article 110-3(B) and voids all
warr
anties.
1. For Wooden Joists: Use the Centering Notches (4) located on the Plaster Frame to position the Fixture.
Extend the Bar Hangers (6), use joist alignment tabs to locate fixture and hammer the 4 Nails (7) into Joists (8)
(Fig. 1). Drive additional nails through holes in Bar Hanger for alternate support if required.
2. For Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar
Hanger Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11)
downward to a vertical position (Fig. 3). Secure housing to the support structure with tie wire (supplied by
others) in the holes supplied. Sheetmetal screws (supplied by others) can also be used in the holes supplied
(20).
3. Locate Housing along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12) on
the Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement. Bar Hangers (6)
may be installed in alternate Slots (23) if mounting conditions require.
4. As desired, hanger bars (6) may be shortened at score mark to fit tight mounting conditions and joist
alignment tabs removed to adjust vertically as needed by breaking off with pliers.
5. Unsnap Junction Box Cover (14) by lifting the Leaf Spring (24).
6
. Run supply wires through UL Listed connectors (not supplied) in one of the five Pryouts (15) on the Junction
Box (16) or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect
Supply Wires (19) as shown in Fig 4 & 5. Replace Cover.
7. Select a Trim from the Wattage Label inside the Housing. Use Only Lamp Types approved for the Trim
chosen. DO NOT EXCEED MAXIMUM LISTED WATTAGE(S)!
INSTRUCTION SHEET MUST BE REMOVED FROM FIXTURE
PRIOR TO ENERGIZING.
Page view 0
1 2

Summary of Contents

Page 1 - Instruction

InstructionSheetPart No....With representatives offices in principal cities throughout North America.Copyright

Page 2 - WIRING DIAGRAM

InstructionSheetPart No............With representatives offices in principal cities throughout North America.Copyright

Comments to this Manuals

No comments